User Tools

Site Tools


sensors:tiltmeter

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
sensors:tiltmeter [2012/09/11 15:08]
karina [Performance Specifications (1*)]
sensors:tiltmeter [2013/10/21 13:58]
claes [Software]
Line 10: Line 10:
 |User manual| {{:sensors:tcm_user_manual_r05.pdf|Download}}| |User manual| {{:sensors:tcm_user_manual_r05.pdf|Download}}|
 |Data sheet|{{:sensors:tcmxbandmb_datasheet.pdf|Download}} | |Data sheet|{{:sensors:tcmxbandmb_datasheet.pdf|Download}} |
 +
 +===== Software =====
 +{{:sensors:tcm_studio_ver_3_0.msi|TCM Studio 3.0}}
 +
 +{{:sensors:tcmtest.zip|}}
 ===== Links ===== ===== Links =====
  
Line 50: Line 55:
  
 ==== Operating Characteristics ==== ==== Operating Characteristics ====
 +
 +=== I/O Characteristics ===
 +
 ^Parameter^^Value^ ^Parameter^^Value^
 |Communication Interface|TCM XB|Binary RS232 UART| |Communication Interface|TCM XB|Binary RS232 UART|
Line 59: Line 67:
  
  
-(1*) The maximum sample rate is dependent on the strength of the magnetic field, and typically will be from 25 to 32 samples/sec.+(1*) The maximum sample rate is dependent on the strength of the magnetic field, and typically will be from 25 to 32 samples/sec.\\
 (2*) FIR taps set to "0". (2*) FIR taps set to "0".
  
 +=== Power Requirements ===
 +^Parameter^^^Value^
 +|Supply Voltage|TCM XB||3.6 to 5 VDC (unregulated)|
 +|:::|TCM MB||3.3 to 5 VDC (unregulated)|
 +|Average Current Draw|TCM XB|@ max. sample rate|20 mA typical|
 +|:::|:::|@ 8 Hz sample rate|16 mA typical|
 +|:::|TCM MB|@ max. sample rate|17 mA typical|
 +|:::| ::: |@ 8 Hz sample rate|13 mA typical|
 +|Peak Current Draw|During application of external power||120 mA pk, 60 mA avg over 2 ms|
 +|:::|During logical power up/down or Sync Trigger||100 mA pk, 60 mA avg over 4 ms|
 +|Sleep Mode Current Draw|||0.3 mA typical|
 +
 +
 +
 +
 +=== Environmental Requirements ===
 +^Parameter^Value^
 +|Operating Temperature (1*)|-40C to +85C|
 +|Storage Temperature|-40C to +85C|
 +
 +(1*) To meet performance specifications, recalibration may be necessary as temperature varies.
 ===== TCM Pin Descriptions ===== ===== TCM Pin Descriptions =====
-^Pin number^TCM XB^^+^Pin number^   TCM XB    ^^
 ^:::^9 pin connector^Pigtailed cable wire color^ ^:::^9 pin connector^Pigtailed cable wire color^
 |1|GND|Black| |1|GND|Black|
sensors/tiltmeter.txt · Last modified: 2021/08/14 04:21 (external edit)