 ====== PNI TCM-XB ForceFieldsensor ====== ====== PNI TCM-XB ForceFieldsensor ======
-This Tiltmeter from the company [[http://www.pnicorp.com/|PNI]] and the sensor is the [[http://www.pnicorp.com/products/fieldforce-tcm|fieldforce-tcm]]. All information is copied from the homepage of the company.+This Tiltmeter from the company [[http://www.pnicorp.com/|PNI Sensor Corporation]] and the sensor is the [[http://www.pnicorp.com/products/fieldforce-tcm|fieldforce-tcm]]. All information is copied from the homepage of the company. 
 + 
 +{{:sensors:pni_tcm.jpg?200|}}
  
  
 box, usb-rs232 converter, usb-plug + cap, sensor box, usb-rs232 converter, usb-plug + cap, sensor
  
 +===== Documentation =====
 +|User manual| {{:sensors:tcm_user_manual_r05.pdf|Download}}|
 +|Data sheet|{{:sensors:tcmxbandmb_datasheet.pdf|Download}} |
 +
 +===== Software =====
 +{{:sensors:tcm_studio_ver_3_0.msi|TCM Studio 3.0}}
 +
 +{{:sensors:tcmtest.zip|}}
 +===== Links =====
  
  
Line 14: Line 25:
  
 http://answers.ros.org/question/10546/pni-digital-compass-driver/#16791 http://answers.ros.org/question/10546/pni-digital-compass-driver/#16791
 +
 +===== PRODUCT Specifications =====
 +
 +==== Performance Specifications (1*) ====
 +
 +^**Parameter**^^^^**Value**^
 +|Heading|Accuracy|≤65° of tilt after full range calibration||<0.3° rms|
 +| ::: | ::: |≤80° of tilt after full range calibration||<0.5° rms|
 +| ::: | ::: |≤5° of tilt after 2D calibration||<2.0° rms|
 +| ::: | ::: |≤2 times the calibration tilt angle after limited-tilt calibration (2*)||<0.2° rms|
 +| ::: |Resolution|||0.1°|
 +| ::: |Repeatability|||0.05° rms|
 +|Tilt (Pitch & Roll)|Range|Pitch||± 90°|
 +| ::: | ::: |Roll||± 180°|
 +| ::: |Accuracy|Pitch||0.2° rms|
 +| ::: | ::: |Roll|≤65° of pitch|0.2° rms|
 +| ::: | ::: | ::: |≤80° of pitch|0.4° rms|
 +| ::: | ::: | ::: |≤86° of pitch|1.0° rms|
 +| ::: |Resolution|||0.01°|
 +| ::: |Repeatability|||0.05° rms|
 +|Maximum Operational Dip Angle (3*)||||85°|
 +|Magnetometers||Calibrated Field Range||± 125 μT|
 +| ::: ||Resolution||0.05 μT|
 +| ::: ||Repeatability||± 0.1 μT|
 +
 +(1*) Specifications are subject to change. Assumes the TCM is motionless and the local magnetic field is clean relative to the calibration. \\
 +(2*) For example, if the calibration was performed over ±10° of tilt, then the TCM would provide <2° rms accuracy over ±20° of tilt.\\
 +(3*) Performance at maximum operational dip angle will be somewhat degraded.
 +
 +==== Operating Characteristics ====
 +
 +=== I/O Characteristics ===
 +
 +^Parameter^^Value^
 +|Communication Interface|TCM XB|Binary RS232 UART|
 +| ::: |TCM MB|Binary CMOS/TTL UART|
 +|Communication Rate||300 to 115200 baud|
 +|Maximum Sample Rate (1*)||≈30 samples/sec|
 +|Time to Initial Good Data (2*)|Initial power up|<210 ms|
 +| ::: |Sleep mode recovery|<80 ms|
 +
 +
 +(1*) The maximum sample rate is dependent on the strength of the magnetic field, and typically will be from 25 to 32 samples/sec.\\
 +(2*) FIR taps set to "0".
 +
 +=== Power Requirements ===
 +^Parameter^^^Value^
 +|Supply Voltage|TCM XB||3.6 to 5 VDC (unregulated)|
 +|:::|TCM MB||3.3 to 5 VDC (unregulated)|
 +|Average Current Draw|TCM XB|@ max. sample rate|20 mA typical|
 +|:::|:::|@ 8 Hz sample rate|16 mA typical|
 +|:::|TCM MB|@ max. sample rate|17 mA typical|
 +|:::| ::: |@ 8 Hz sample rate|13 mA typical|
 +|Peak Current Draw|During application of external power||120 mA pk, 60 mA avg over 2 ms|
 +|:::|During logical power up/down or Sync Trigger||100 mA pk, 60 mA avg over 4 ms|
 +|Sleep Mode Current Draw|||0.3 mA typical|
 +
 +
 +
 +
 +=== Environmental Requirements ===
 +^Parameter^Value^
 +|Operating Temperature (1*)|-40C to +85C|
 +|Storage Temperature|-40C to +85C|
 +
 +(1*) To meet performance specifications, recalibration may be necessary as temperature varies.
 +===== TCM Pin Descriptions =====
 +^Pin number^   TCM XB    ^^
 +^:::^9 pin connector^Pigtailed cable wire color^
 +|1|GND|Black|
 +|2|GND|Grey|
 +|3|GND|Green|
 +|4|NC|Orange|
 +|5|NC|Violet|
 +|6|NC|Brown|
 +|7|UART Tx|Yellow|
 +|8|UART Rx|Blue|
 +|9|+5 VDC|Red|
 +