 ^ ^Minimum^Typical^Maximum^ ^ ^Minimum^Typical^Maximum^
 |Supply voltage LMS100/LMS111/LMS151 SELV or PELV as per IEC 60364H4H41 (2005H12)|10.8 V|24 V|30 V| |Supply voltage LMS100/LMS111/LMS151 SELV or PELV as per IEC 60364H4H41 (2005H12)|10.8 V|24 V|30 V|
-||||| +|Supply voltage LMS122/LMS123 SELV or PELV as per IEC 60364H4H41 (2005H12)|9 V|24 V|30 V
-||||| +|Permissible residual ripple| | |±5%
-||||| +|Supply voltage for the LMS111/LMS151 heating|19.2 V|24 V|28.8 V
-||||| +|Switch on current| | |2 A
-||||| +|Operating current at 24 V without output load| |0.35 A|0.5 A
-||||| +|Operating current with max. output load| |0.65 A|0.8 A
-||||| +|Operating current with maximum heating performance| |2.3 A|2.5 A
-||||| +|Power consumption without output load| |8.4 W|12 W
-||||| +|Power consumption with maximum output load| |16 W |20 W
-||||| +|Power consumption with maximum heating performance| |55 W60 W
-||||| +|Electrical connection LMS111/LMS151|Round M12 plug connector||| 
 +|Electrical connection LMS100/LMS122/LMS123|System plug with screw terminal block||| 
 +|**Technical specifications**, screw terminals|||| 
 +|- Cross-section of rigid cores (American Wire Gauge — AWG)|0.14 mm2 (approx. 26 AWG)| |1.5 mm2 (approx. 16 AWG)| 
 +|- Cross-section of flexible cores (American Wire Gauge — AWG)|0.14 mm2 (approx. 26 AWG)| |1.0 mm2 (approx. 18 AWG)| 
 +|- Insulation stripping length for the cores| |5 mm (0.2 in)| | 
 +|- Screw tightening torque|0.22 Nm| |0.3 Nm| 
 +|**Cable length** for device power supply at 24 V|||| 
 +|- With 1 mm2 wire cross-section (approx. 18 AWG)| | |220 m (721.78 ft)| 
 +|- With 0.5 mm2 wire cross-section (approx. 22 AWG)| | |110 m (360.89 ft)| 
 +|With 0.25 mm2 wire cross-section (approx. 24 AWG)| | |50 m (164.04 ft)| 
 +|**Cable length** for heating at 24 V|||| 
 +|- With 1 mm2 wire cross-section (approx. 18 AWG)| | |45 m (147.64 ft)| 
 +|- With 0.5 mm2 wire cross-section (approx. 22 AWG)| | |20 m (65.62 ft)| 
 +|- With 0.25 mm2 wire cross-section (approx. 24 AWG)| | |10 m (32.81 ft)| 
 +|**Cable length** for device power supply at 12 V|||| 
 +|- With 1 mm2 wire cross-section (approx. 18 AWG)| | |20 m (65.62 ft)| 
 +|- With 0.5 mm2 wire cross-section (approx. 22 AWG)| | |10 m (32.81 ft)| 
 +|- With 0.25 mm2 wire cross-section (approx. 24 AWG)| | |5m (16.40 ft)| 
 +|**Switching inputs**|||| 
 +|- Number|2||| 
 +|- Input resistance on HIGH| |2 kΩ| | 
 +|- Voltage for HIGH|11 V|24 V|30 V| 
 +|- Voltage for LOW| |0 V|5 V| 
 +|- Input capacity| |15 nF| | 
 +|- Static input current|6 mA| |15 mA| 
 +|**Dynamic control inputs**|||| 
 +|- Number|2||| 
 +|- Input resistance on HIGH| |2 kΩ| | 
 +|- Voltage for HIGH|11 V|24 V|30 V| 
 +|- Voltage for LOW|-3 V|0 V|5 V| 
 +|- Input capacity| |1 nF| | 
 +|- Static input current|6 mA| |15 mA| 
 +|- Duty cycle (Ti/T)| |0.5| | 
 +|- Input frequency| | |100 kHz| 
 +|- Current load per incremental encoder| |50 mA|100 mA| 
 +|**Velocity range that can be sampled**|||| 
 +|- Forward|From +100 mm/s to +20,000 mm/s (3.94 in/s to +788 in/s)||| 
 +|- Backward|From –10 mm/s to –20,000 mm/s (–0.39 in/s to –788 in/s)||| 
 +|**Incremental encoders that can be evaluated**|||| 
 +|- Type|Two-channel rotary encoder with 90° phase offset||| 
 +|- Enclosure rating|IP 54| | | 
 +|- Supply voltage|U<sub>V</sub> – 3 V| |U<sub>V</sub>
 +|- Outputs required on the incremental encoders|Push&/Pull||| 
 +|- Pulse frequency| | |100 kHz| 
 +|- Number of pulses per cm|50| | | 
 +|- Cable length (screened)| | |10 m (32.81 ft)| 
 +|**Digital switching outputs** LMS100/111/151|||| 
 +|- Number|3||| 
 +|- Voltage drop load| |2 V| | 
 +|- Maximum switching current| | |140 mA| 
 +|- Current limiting (after 5 ms at 25°C (77 °F)|100 mA| |200 mA| 
 +|- Power-up delay|Negligible||| 
 +|- Switch off time| |0.8 ms|2 ms| 
 +|**Relay switching outputs** LMS122/123|||| 
 +|- Number|2||| 
 +|- Switching capacity| | |DC 30 W/ AC 37,5 VA| 
 +|- Switching voltage| | |DC 110 V/ AC 125 V| 
 +|- Switching current| | |0.5 A at DC 30 V| 
 +|- Switching capacity| | |10μA DC 10 mV| 
 +|- Switching cycles|10<sup>5</sup>| | | 
 +|- Power-up delay| |2 ms|4 ms| 
 +|- Switch off time| |2 ms|4 ms| 
 +|**Serial auxiliary interface**|||| 
 +|- Communication protocol|RSH232 (proprietary)||| 
 +|- Transmission speed|9,600 Baud|57.6 kBd|115.2 kBd| 
 +|**Serial host interface**|||| 
 +|- Communication protocol|RSH232 (proprietary)||| 
 +|- Transmission speed (selectable)|9,600 Baud|57.6 kBd|115.2 kBd| 
 +|- Cable length at 38.400 kBd and wire cross- section 0.25 mm2 (approx. 24 AWG)| | |15 m (49.21 ft)| 
 +|- Galvanic de-coupling|Yes||| 
 +|- Wire cross-section of the connecting cable| | |0.25 mm2 (approx. 24 AWG)| 
 +|Ethernet|10/100 MBit/s||| 
 +|CAN|20 kBit/s, 500 kBit/s, 1 Mbit/s|||
  