User Tools

Site Tools


sensors:lsm111

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
sensors:lsm111 [2012/09/10 16:11]
karina [Electrical data]
sensors:lsm111 [2012/12/05 17:13]
dimitrios
Line 10: Line 10:
 LMS 1XX LMS 1XX
 {{:sensors:How to store data on LMS1XX.pdf|How to store data using SICK Laser}} {{:sensors:How to store data on LMS1XX.pdf|How to store data using SICK Laser}}
 +
 +LMS 1XX
 +{{:sensors:LMS1xx_LMS5xx_TiM3xx_JEF300_JEF500 Telegrams.pdf|LMS1xx Developer's guide}}
  
 {{:sensors:lms100.gif?200|}} {{:sensors:lms100.gif?200|}}
Line 154: Line 157:
 |- Type|Two-channel rotary encoder with 90° phase offset||| |- Type|Two-channel rotary encoder with 90° phase offset|||
 |- Enclosure rating|IP 54| | | |- Enclosure rating|IP 54| | |
-|- Supply voltage|Uv – 3 V| |Uv|+|- Supply voltage|U<sub>V</sub> – 3 V| |U<sub>V</sub>|
 |- Outputs required on the incremental encoders|Push&/Pull||| |- Outputs required on the incremental encoders|Push&/Pull|||
 |- Pulse frequency| | |100 kHz| |- Pulse frequency| | |100 kHz|
Line 162: Line 165:
 |- Number|3||| |- Number|3|||
 |- Voltage drop load| |2 V| | |- Voltage drop load| |2 V| |
-||||| +|- Maximum switching current| | |140 mA
-||||| +|- Current limiting (after 5 ms at 25°C (77 °F)|100 mA| |200 mA
-||||| +|- Power-up delay|Negligible||| 
-||||| +|- Switch off time| |0.8 ms|2 ms
-||||| +|**Relay switching outputs** LMS122/123|||| 
-||||| +|- Number|2||| 
-||||| +|- Switching capacity| | |DC 30 W/ AC 37,5 VA
-||||| +|- Switching voltage| | |DC 110 V/ AC 125 V
-||||| +|- Switching current| | |0.5 A at DC 30 V
-||||| +|- Switching capacity| | |10μA DC 10 mV
 +|- Switching cycles|10<sup>5</sup>| | | 
 +|- Power-up delay| |2 ms|4 ms| 
 +|- Switch off time| |2 ms|4 ms| 
 +|**Serial auxiliary interface**|||| 
 +|- Communication protocol|RSH232 (proprietary)||| 
 +|- Transmission speed|9,600 Baud|57.6 kBd|115.2 kBd| 
 +|**Serial host interface**|||| 
 +|- Communication protocol|RSH232 (proprietary)||| 
 +|- Transmission speed (selectable)|9,600 Baud|57.6 kBd|115.2 kBd| 
 +|- Cable length at 38.400 kBd and wire cross- section 0.25 mm2 (approx. 24 AWG)| | |15 m (49.21 ft)| 
 +|- Galvanic de-coupling|Yes||| 
 +|- Wire cross-section of the connecting cable| | |0.25 mm2 (approx. 24 AWG)| 
 +|Ethernet|10/100 MBit/s||| 
 +|CAN|20 kBit/s, 500 kBit/s, 1 Mbit/s|||
  
 ===== (1*)(2*)(3*) ===== ===== (1*)(2*)(3*) =====