User Tools

Site Tools


robots:armadillo:hardware:battery

This is an old revision of the document!


Battery

The battery on the Armadillo Scout is a 48 VDC (52.2 VDC) 160 Ah Lithium Yttrium batterypack consisting of 16 3.2 VDC batterycells.

Bettarycell

Specifications

Model nameLFP160AHA Older product marking TS-LFP160AHA, TS-LYP160AHA
Nominal voltage 3.2 V Operating voltage under load is 3.0 V
Capacity 160 AH +/- 5%
Operating voltage max 4.0V - min 2.8V At 80% DOD
Deep discharge voltage 2.5 VThe cells is damaged if voltage drops bellow this level
Maximal charge voltage 4.0 VThe cells is damaged if voltage exceeds this level
Optimal discharge current < 80 A 0.5 C
Maximal discharge current < 480 A 3 C, continuous for max 15 minutes from full charge
Max peak discharge current < 3200 A 20 C, maximal 5 seconds in 1 minute
Optimal charge current < 80 A
Maximal charge current < 480 A
Maximal continuous operating temperature80 °C The battery temperature should not increase this level during charge and discharge
Dimensions 182x71x277 mm Millimeters (tolerance +/- 2 mm)
Weight 5.8 kg Kilograms (tolerance +/- 150g)

Dimensions

Initial Charge

The above is the offical TS instruction for the first charge of the LFP batteries. Please see more details here.

Question: Is there a difference between charging to 4.0V and 4.2V?1)

Generally there is no signicicant difference. The voltage increase from 4.0V to 4.2V is very fast. If you charge to 4.2V it is 100% DOD cycle. If you charge to 4.0 it is 97% and more of the DOD cycle.

Question: How should new cells 3.2V 40AH, 60AH, 90AH, 100 AH, etc. be formed before first usage?2)

The new 3.2V LFP cells delivered from the warehouse are partially charged. However before the first use, it is essential to charge each cell to full capacity. The initial charging should be done with the charging current set to less than 1C (typically 0.5C), till the voltage level of 4.0 V is reached.

There is no other need for LFP 3.2V cells to be formatted or otherwise specially prepared for the use. After the first charge to full, the cell is ready to be used for use.

The above charging rule is also applied to the initial charge after the cell has been unused or stored for a long time. If not used more than 1 month, it is recommended to make again an initial charge to full.

Important: if you plan not to use the cells for a long time, before storing you must charge cells to full. In the case of storage longer than 1 year, it is required to recharge each cell after 12 months to full.

Battery Terminals

Never apply excessive force to the terminal connectors!

Applying excessive force to tighten or release the bolts of the terminal connectors can cause whole terminal to move (rotate). The result is a damage of the internal structure of the cell that cannot be repaired. No warranty can be applied for such kind of the cell abuse.